Sophisticated complete HPLC systems offer an easy and improved liquid chromatography method for separating mixture compounds essential for further quantification or identification analyses. Instead of the sample traveling through the column by gravitational means, this equipment utilizes a forced air pressure push to achieve faster results. Pumps maintain a consistent flow rate while ultra-sensitive detectors assist with accurate retention times. For better separations, the complete HPLC systems allow pre-packed stationary phase materials with smaller particle sizes.

Sophisticated complete HPLC systems offer an easy and improved liquid chromatography method for separating mixture compounds essential for further quantification or identification analyses. Instead of the sample traveling through the column by gravitational means, this equipment utilizes a forced air pressure push to achieve faster results. Pumps maintain a consistent flow rate while ultra-sensitive detectors assist with accurate retention times. For better separations, the complete HPLC systems allow pre-packed stationary phase materials with smaller particle sizes.


46  results were found

Sort Results

List View Easy View
SearchResultCount:"46"
Description: Chromaster 5110 PumpAccuracy +/- 1% Or +/- 2 ul/Min, Whichever Is Greater (0.010 To 5.000 Ml/Min)Precision +/- 0.075 % Rsd Or 0.02 Min Sd Maximum Pressure 40 Mpa (0.001 To 5.000 Ml/Min), 20 Mpa (5.001 To 9.999 Ml/Min)
Catalog Number: 76493-058
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Column oven, Tall, High capacity, high precision, Control system Peltier block cooling/heating with air circulation, Temperature setting range: 4-90 deg, Tool-less universal fitting Moment-Enhancing Mechanism (MEM) column fitting max. Pressure: 1400 bar
Catalog Number: 76493-026
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Chromaster 5160 Pump With Automatic Purge Valve Accuracy +/- 1% Or +/- 2 ul/Min, Whichever Is Greater (0.010 To 5.000 Ml/Min) Precision +/- 0.075 % Rsd Or 0.02 Min Sd Maximum Pressure 60 Mpa (0.001 To 2.500 Ml/Min), 30 Mpa (2.501 To 5.000 Ml/Min)
Catalog Number: 76493-064
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Autosampler, Chromaster 5260, Capacity: 120 Vials X1.5 Ml (Standard), 195 X 1Ml, 72 X 4Ml, 2 X Mtp, Injection Volume: 0.1 ul To 50 ul (100Ul Loop, Standard), Injection Volume Precision: 0.2% Rsd (10-ul Cut Injection)
Catalog Number: 76493-092
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Chromaster 5310 Column Oven, Range: [Room Temperature - 15 deg C] To [Room Temperature + 60 deg C], Setting Range: 1 To 85 deg C, Accuracy: +/- 1 deg C, Temp Control Precision: Sd 0.2 deg C, Column Capacity: 3 Each 300Mm Columns, Safety: Built-In Vapor/Leak Sen
Catalog Number: 76493-132
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Chromaster 5260 Autosampler With Cooling, Setpoint Range (1-45 deg C, 1 deg C Steps)* Vials (Rt-21 deg C) To (Rt+25 deg C), * Mtp (Rt-15 deg C) To (Rt+20 deg C)
Catalog Number: 76493-128
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Chromaster 5410 Uv Detector, Wavelength Range: 190 To 600 Nm, Noise: < 0.5 X 10-5 Au, Drift: < 0.1 X 10-4 Au/H
Catalog Number: 76493-142
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Chromaster 5420 Uv-Vis Detector Noise: < 0.5 X 10-5 Au Drift: < 0.1 X 10-4 Au/H Wavelength Range: 190 To 900 Nm
Catalog Number: 76493-144
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Chromaster 5450 Refractive Index DetectorRefractive Index Range: 1.0 To 1.75 Noise: < 2.5 Nriu Drift: < 0.2 Uriu
Catalog Number: 76493-148
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Chromaster 5430 Diode Array DetectorNoise: < 0.5 X 10-5 Au Drift: < 0.5 X 10-3 Au/H Wavelength Range: 190 To 900 Nm
Catalog Number: 76493-146
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Chromaster 5440 Fluorescence Detector, Emission Wavelength: 250 To 900 Nm, Excitation Wavelengths: 200 To 850 NmSignal To Noise Ratio: Greater Than Or Equal To 1200: 1 For Raman Band Of Water At 350 Nm (Baseline Method), Wavelength Accuracy: +/- 3 Nm
Catalog Number: 76493-174
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Chromaster 5280 Autosampler Requires Chromaster Organizer (892-0806) Or 150W (892-0854) Power Supply.
Catalog Number: 76493-178
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Cabinet For Solvent Bottles. (Galon Bottle X 2, 500Ml X 3))Power Supply Function For Pump, As, Ifc Board, Detectors.
Catalog Number: 76493-180
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Chromaster 5280 Autosampler With CoolingRequires Chromaster Organizer (892-0806) Or 150W (892-0854) Power Supply.
Catalog Number: 76493-176
Supplier: HITACHI HIGH-TECH AMERICA, INC.