CrossLab Ion Lenses for ICP-MS, Agilent Technologies

Supplier: AGILENT TECHNOLOGIES, INC (CSD)
G3280-67037 G3280-67039 G8400-67001 G3280-60612 G3280-67035 G3280-67038 G3666-60302 G3666-60303 G3666-67038 G3666-67300 G3666-67400 G8400-00240 G8400-60217 G8400-67002 G8400-67003 G1833-65592 G1833-65593 G3280-01650 G3280-20628 G3280-20646 G3280-20653 G3280-60609 G3280-60613 G3280-60615 G3280-67044 G3666-20404 G3666-60402 G3666-60403 G3666-60502 G3666-60503 G3666-67044 G3666-67500 G3666-67600 G8400-60215 G8400-60216 G8400-60218 G8400-60219 G8400-67047
AGG3280-67037KT 756.7 USD
AGG3280-67037 AGG3280-67039 AGG8400-67001 AGG3280-60612 AGG3280-67035 AGG3280-67038 AGG3666-60302 AGG3666-60303 AGG3666-67038 AGG3666-67300 AGG3666-67400 AGG8400-00240 AGG8400-60217 AGG8400-67002 AGG8400-67003 AGG1833-65592 AGG1833-65593 AGG3280-01650 AGG3280-20628 AGG3280-20646 AGG3280-20653 AGG3280-60609 AGG3280-60613 AGG3280-60615 AGG3280-67044 AGG3666-20404 AGG3666-60402 AGG3666-60403 AGG3666-60502 AGG3666-60503 AGG3666-67044 AGG3666-67500 AGG3666-67600 AGG8400-60215 AGG8400-60216 AGG8400-60218 AGG8400-60219 AGG8400-67047
CrossLab Ion Lenses for ICP-MS, Agilent Technologies
Chromatography Supplies Chromatography Spare Parts
Replacement Omega ion extraction lenses for 7700, 7800, 7900, 8800, 8900 ICP-MS with x-lens and s-lens.

  • High transmission off-axis or Omega lens arrangement separates the positively charged ions from the photons and neutral particles
  • Routine x-lens or semiconductor, s-lens, ion extraction lenses are available as individual parts or as an assembly
  • A variety of additional lens components and supplies are available: screw and spacer sets, lens cleaning and polishing kits
  • The extraction lenses are placed just behind the skimmer cone and mounted on the skimmer base
  • They are used to extract positive ions and accelerate them to into the ORS and MS detector

Ion extraction lenses 7700, 7800, 7900, 8800, 8900 ICP-MS perform an essential function of separating the ions from the photons and residual neutral material for the lowest background signal and highest sensitivity with efficient interference removal.;Agilent uses a high transmission off-axis, Omega lens design that is tuned for optimal performance across the mass range.;Replacement Omega ion extraction lens assemblies and individual lens components for replacement and maintenance routine, x-lens, or semiconductor, s-lens, configuration.

Agilent uses a high transmission off-axis, Omega lens design that is tuned for optimal performance across the mass range. Replacement Omega ion extraction lens assemblies and individual lens components for replacement and maintenance routine, x-lens, or semiconductor, s-lens, configuration.