Tygon® ND-100-65 Medical/Surgical Tubing, Saint-Gobain Performance Plastics

Supplier: Saint Gobain Life Sciences
ADF02004 ADF02002 ADF00002 ADF00003 ADF00037 ADF02038 ADF00001 ADF02017 ADF00016 ADF02018 ADF00018 ADF02007 ADF02006 ADF00006 ADF00011 ADF00013 ADF00012 ADF00004 ADF00005 ADF02029 ADF00028 ADF00023 ADF00022 ADF00024 ADF00010 ADF00009 ADF00038 ADF00036 ADF00019 ADF00017 ADF00053 ADF00027 ADF00029 ADF00046
89403-912PK 238.1 USD
89403-912 89403-948 89403-950 89403-952 89403-954 89404-032 89404-034 89404-036 89404-038 89404-040 89404-042 89404-044 89404-046 89404-048 89404-050 89404-052 89404-054 89404-056 89404-058 89404-060 89404-062 89404-272 89404-274 89404-276 89404-278 89404-282 89404-284 89404-286 89404-288 89404-290 89404-292 89404-294 89404-298 89404-312 89404-352 89404-354 89404-356 89404-358 89404-360 89404-364 89404-366 89404-368 89404-370
Tygon® ND-100-65 Medical/Surgical Tubing, Saint-Gobain Performance Plastics
Tubing Transfer Tubing
Tygon® ND-100-65 Medical/Surgical Tubing has been specifically formulated for medical device manufacturers that require a non-DEHP plasticized material.

Crystal clear for easy visualization of fluid flow. Ideal for contact with bodily fluids. Non-wetting surface permits complete drainage. Withstands EtO, gas, and gamma sterilization.

Tygon® ND-100-65 tubing is made from a biocompatible non-DEHP polymer material developed specifically for blood and contact medical device needs. It meets USP Class VI, ISO 10993, European Pharmacopoeia 3.1.1.2, and European REACH requirements. It is also non-hemolytic and non pyrogenic.

This tubing formulation sets the new standard for performance and durability in blood contact applications. Based upon a unique chemistry developed by Saint-Gobain, Tygon® ND Series tubing was formulated to be Registration, Evaluation, Authorization and restriction of CHemical substances (REACH) compliant. DEHP levels are less than 1000 ppm. During the extrusion process, individual process dimensions are maintained and monitored through in-line micrometers and off-line verification with computerized imaging equipment. Consistent with many medical tubing requirements, ND-100-65 material can be effectively bonded/welded using heat, electronic (RF)/ultrasonic, solvent, and adhesive methods. Factors to be considered when selecting the components include security of the bond required, effect on the integrity of the materials to be joined, and presence of residues or extractable that may affect biocompatibility. When bonding procedures are not used, mechanical clamps are recommended to provide secure attachment.
Order Now

Learn more

About VWR

Avantor is a vertically integrated, global supplier of discovery-to-delivery solutions for...

Learn more About VWR